Case Study: Eco-Tec H2S Scrubber Purifies Gas For Reuse In Greenhouse
By Eco-Tec Inc.
A landfill gas scrubber was required for the removal of H2S thereby allowing the gas to be used as a source of both heat and CO2 to a greenhouse on the site. 3,085 Nm3/hour of saturated landfill gas is extracted from the wells at a maximum temperature of 40°C and with a H2S concentration of 50 ppmv. The greenhouse specified that the gas needs to be provided to them with an H2S concentration less than 1 ppmv and dried to a maximum dew point temperature of 3°C.
|
|